2022-07-30 14:46:04 -03:00

102 lines
3.5 KiB
HTML

<!DOCTYPE html PUBLIC "-//W3C//DTD HTML 4.01 Transitional//EN">
<html>
<head>
<title>ALE User Manual: Devices</title>
<style type="text/css">
TABLE.ba { max-width: 678; text-align: center; padding-bottom: 15; padding-top: 5}
TABLE.inline { padding-right: 300; clear: left}
TD.text_table {padding-left: 2; padding-right: 2; border-width: 1}
H2 {clear: left}
P {max-width: none; padding-right: 300; clear: left}
BLOCKQUOTE {padding-right: 400 }
LI {max-width: 640; clear: left}
P.footer {max-width: none; width: auto; padding-left: 0}
P.header {max-width: none; width: auto; padding-left: 0}
HR.main {max-width: 640; clear: left; padding-left: 0; margin-left: 0}
HR.footer {clear: both}
</style>
</head>
<body>
<table align=right valign=top width=160>
<td valign=top height=600 width=160>
<a href="http://auricle.dyndns.org/ALE/">
<big>ALE</big>
<br>
Image Processing Software
<br>
<br>
<small>Deblurring, Anti-aliasing, and Superresolution.</small></a>
<br><br>
<big>
Local Operation
</big>
<hr>
localhost<br>
2684415918<br>
</table>
<p><b>[ <a href="../">Up</a> ]</b></p>
<h1>ALE Devices</h1>
<p>Device specification is optional. Specifying a device allows automatic
determination of <a href="../rendering/psf/">point-spread functions</a>,
refinement of the correspondence between incident light and pixel values (e.g.
power law), and refinement of certainty calculation.
<pre>
--device &lt;d&gt; Set the capture device to &lt;d&gt;.
</pre>
<p>Available devices are as follows:</p>
<table border>
<tr><td>canon_300d_raw_linear<td>Canon 300D (Digital Rebel) raw, linear data. [0.7.2 and later]
<tr><td>canon_300d_raw_linear+50mm_1.4<td>Canon 300D with EF 50mm f/1.4 lens, unspecified aperture.
<tr><td>canon_300d_raw_linear+50mm_1.4@1.4<td>Canon 300D with EF 50mm f/1.4 lens, aperture 1.4.
<tr><td>canon_300d_raw_linear+50mm_1.8<td>Canon 300D with EF 50mm f/1.8 lens, unspecified aperture.
<tr><td>canon_300d_raw_linear+85mm_1.8<td>Canon 300D with EF 85mm f/1.8 lens, unspecified aperture.
<tr><td>ov7620_raw_linear<td>OmniView OV7620 in raw RGB, linear mode. [0.7.0-patch1 and later]
<tr><td>xvp610_640x480<td>IBM PC Camera Pro (XVP610) in 640x480 mode.
<tr><td>xvp610_320x240<td>IBM PC Camera Pro (XVP610) in 320x240 mode.
</table>
<p>These device options are described in more detail below.
<h2>Canon 300D (Digital Rebel) [0.7.2 and later]</h2>
<p>Direct support for CRW files depends on the ImageMagick configuration, and
may not be available on all platforms. Dave Coffin's <a
href="http://www.cybercom.net/~dcoffin/dcraw/">dcraw</a> program, invoked with
arguments -d -4, will produce a raw, linear PPM file suitable for use with this
device configuration. JPEG files produced by the 300D cannot be directly used
as inputs for this configuration, since they are gamma-corrected rather than
linear.</p>
<h2>OV7620 [0.7.0-patch1 and later]</h2>
<p>Standard OV7620 drivers may not include options for setting raw RGB or linear
modes. Linux users may apply a <a href="/ov7620/">driver patch</a> to access
these modes. Setting the module option <code>rgb_raw=2</code> places the camera
into the desired mode.</p>
<h2>XVP610</h2>
<p>Users of XVP610 cameras and Linux may wish to apply a <a href="/xvp610/">driver patch</a>. This version of ALE expects that this patch has been applied.